Before flow iron goes into service, ask for a pressure test record that names the piece, the test pressure, the hold time, and the date — and ties the record to the piece by serial number or drawing number. A record missing any of those details does not prove the iron was tested, and iron with no record should be treated as untested until it is tested again. For new iron the record usually comes from the manufacturer or supplier; for used iron it should come from the most recent test, with the tester's name on it.
Why the record matters more than the claim
Every piece of flow iron that goes on a high-pressure line should have been pressure tested before it is put into service. The test itself is straightforward: the piece is filled, pressurized, held, and watched for leaks or pressure loss. But the test only protects the crew and the job if someone can prove it happened — and that proof is the record.
A verbal assurance — “it was tested” — is not a record. Without paper (or a digital file) that names the piece, the pressure, and the date, there is no way to check whether the test covered this piece, whether the pressure matched the service, or whether the test was recent enough to mean anything. When iron changes hands, the record is what travels with it, and a buyer who does not ask for it is buying on trust alone.
What a complete test record includes
- Piece identification: the description, size, union figure, and working pressure of the piece tested — and a serial number, heat number, or drawing number that ties the record to that exact piece.
- Test pressure: the pressure the piece was held at, stated plainly, so it can be checked against the working pressure of the line it will serve.
- Hold time: how long the pressure was held, and whether the pressure stayed steady for the whole hold.
- Test medium: what the piece was filled with for the test, usually water for a hydrostatic test.
- Date and tester: when the test was done and who did it, with a name or signature — a record with no tester and no date is hard to stand behind.
- Result: a clear pass or fail, and, if anything was repaired or retested, a note saying so, with the retest recorded the same way.
How to read a record before you accept the iron
Start by matching the record to the iron in front of you. The size, union figure, and serial or drawing number on the record should match the stamp on the piece. A record that describes a different piece — or no piece at all — proves nothing about the iron you are buying.
Then check the numbers. The test pressure should cover the working pressure of the service the iron will see, and the hold time should be long enough to show a leak if there is one. Check the date, too: a record from years ago says the piece passed once, not that it is sound today, especially if the iron has been in service since. If the date is old or the iron's history since the test is unclear, ask for a fresh test before delivery — and put that request in the RFQ, not in a phone call.
What to do when the record is missing
If the seller cannot produce a test record, treat the iron as untested. That does not mean the iron is bad — it means its condition is unverified, and unverified iron should not go straight onto a pressurized line. The practical answer is to have the iron tested before it goes into service, with the test recorded the way this article describes, and to factor the time for that test into the job plan.
Put the documentation request in writing from the start. When you send an RFQ, ask for the pressure test record with the quote, and list the pieces it should cover. A supplier who tests and documents as a matter of course will have the record ready; a supplier who cannot produce one has told you something useful before any iron changes hands.
Where Sterling can help
Sterling Wellhead stocks new 2-inch FIG 1502, 10,000 PSI flow iron in Jourdanton, Texas 78026, including the T000856 plug valve, 4 ft, 6 ft, and 10 ft pup joints (T000864, T000866, T000855), and Style 10 and Style 50 swivel joints (T000620, T000693). Send the line list, the quantities and drawing numbers, the delivery location, and the required-on-site date, and ask for the pressure test documentation with your RFQ — our team will confirm the configuration by drawing number. Sterling is RFQ-only: contact sales@sterlingwellhead.com or +1 (512) 373-0384.
Frequently asked questions
What pressure should flow iron be tested to?+
The test pressure should be set by the job's requirements and the rated working pressure of the iron. Ask the supplier what pressure each piece was tested to and confirm it covers the service the iron will see. Sterling's stock is 2-inch FIG 1502 flow iron rated to 10,000 PSI working pressure — confirm the test pressure for your line in the RFQ.
How do I know a test record belongs to the iron I am buying?+
Match the record to the piece: the size, union figure, and serial number or drawing number on the record should match the stamp on the iron. If the record has no serial or drawing number, or the numbers do not match, ask the seller to confirm which piece the record covers before you accept it.
Does new flow iron need a pressure test record too?+
Yes. New iron should come with documentation from the manufacturer or supplier showing it was tested before it left the yard. Ask for the record with your RFQ, just as you would for used iron — new does not mean undocumented.